• M 1700 VENTILATOR - ALLIED MEDICAL TECH

Product Specification

Tidal Volume 2500ml

Brand Allied

Model Name/Number M1700

Respiratory Rate 80 bpm

Mounting Type ICU

Relative Humidity 85%

Apnea Time 60 sec

Power Backup 180 mins. internal battery backup

Trigger sensitivity Pressure trigger OFF,0.5 to 20 cm H2O,Flow trigger OFF,0.5 to 20 LPM

Inspiratory time 24 sec

Weight 7.8 kgs. (main unit with battery)

Inspiratory Pressure 80 cm H2O (Peep+Pins less than 100cm H2O)

Operation Temperature 40 Degree C

Display Screen 8 Inch Screen with Touch Control & Rotary Knob

Parameters Set Parameters / Measured Parameters / Alarm Status / IE Ratio

Waveform Pressure-Time,Flow-Time,Volume-Time

Loop Pressure-Volume,Flow-Volume,Minute Volume

Modes PACV,PSIMV,VACV,VSIMV,AUTO (Emergency Quick Start),Spont+,PRVC

Pressure support 60 cm H2O (PEEP+PSV less than 100cm H2O)

Rise Time in PCV Fast,Medium,Slow (2 sec)

Apnea BackUp Type PACV,VACV Mode

Trend 72 hrs

Enable inhalation trigger En sense 80% of Inhalated volume

Exhalation trigger Sensitivity Ex trig 80% of peak flow in Exhalation

Inspiratory Pressure limit 80 cm H2O in PRVC

Suitable Body Weight Volume Mode 10 - 150 kg,Pressure mode 1 - 150 kg

Nebulizer time 180 mins (3 Hours)

Altitude Volume Compensated 5000 [m]

Room Air Temperature 50 Degree C

Power AC 100 V

PEEP and CPAP 50 cm H2O

Dimensions 250mm x 156mm x 371mm (W x D x H)

Product Description

Our ICU Ventilators are designed with utmost precision under the supervision of experienced professionals, our offered products are widely appreciated in hospitals, nursing homes, clinics and other medical sectors for their accuracy, reliable operation, simple design, high efficiency and longer service life. 



Features:

Invasive as well as Non-Invasive Ventilation

Pressure & Flow waveforms with Trends Facility

Altitude compensation

FiO2 Measurement

Suitable for both dual as well as single limb breathing circuits

Patient History storage capability

Automatic Parameters adjustment of the patient according to Height & Weight

Battery Backup: 4 Hrs

Extended battery backup (optional): 4 Hrs

Touchscreen, as well as the knob, operated

Shock Resistant (Drop Test compliant)

Nebulizer: 10 180 minutes

Inspiration hold: Measures patient  lung compliance and resistance, Elasticity, Time constant

Key lock: Key & LCD Touch Screen Lock

Waveform freeze: Freezes the waveform

Alarm silence: Mutes audible alarms for 2 minutes

Alarm Reset: Clears visual indicators and messages

Optional:

EtCO2 Measurement

SpO2 Measurement

Trolley