Product Details
Brand Hamilton
Model Name/Number -C6
Patient Age Group - Paediatric, Adult and Infant
Tidal Volume - Adult: 20 to 2000 ml, Pediatric: 20 to 2000 ml, Neonatal: 2 to 300 ml
Ventilation Mode- (S)CMV, SIMV, APVcmv/(S)CMV+, APVsimv/SIMV+, PCV+, P-SIMV+, DuoPAP, APRV, SPONT, ASV INTELLiVENT-ASV, NIV, NIV-ST, nCPAP-PS, Hi Flow O2
Performance Data -Maximum Inspiratory Flow
260 L/min
Parameter
PEEP/CPAP
Adult/Ped: 0 to 50 cm H2O, Neonatal: 0 to 25 cm H2O
Control
Flow Trigger
Adult/Ped: 0.5 to 20 L/min, Neonatal: 0.1 to 5 L/min
Flow Pattern
Square, 50% decelerating, Sine, 100% decelerating
Standards and Approvals
Classification
Class IIb, continuously operating according to EC directive 93/42/EEC
Certification
EN 60601-1:2006/A1:2013, IEC 60601-1-2:2014, ANSI/AAMI ES60601-1:2005/(R)2012, ISO 80601-2-12:2011, CAN/CSA-C22.2 NO. 60601-1:14, EN ISO 5356-1:2015, ISO 80601-2-55:2011
Declaration
The HAMILTON-C6 was developed in accordance with pertinent international standards and FDA guidelines. The ventilator is manufactured within an EN ISO 13485 and EN ISO 9001, Council Directive 93/42/EEC, Annex II, Article 3 certified quality management system. The ventilator meets the Essential Requirements of Council Directive 93/42/EEC, Annex I
Electromagnetic Compatibility
According to IEC 60601-1-2:2014
Safety Class
Class I, Type B applied part (ventilator breathing system, VBS), type BF applied parts CO2 sensor including CO2 module connector, humidifier, Aerogen system, nebulizer, and SpO2 sensor including SpO2 adapter, continuous operation according to IEC 60601-1
Pneumatic Performance
Oxygen Pressure
2.8 to 6 bar / 41 to 87 psi
Oxygen Connector
DISS (CGA 1240) or NIST
Air Supply
Integrated turbine with lifetime warranty
Inspiratory Outlet (To Patient Port)
Connector: ISO 15 mm ID/22 mm OD conical
Expiratory Outlet (From Patient Port)
Connector (on expiratory valve): ISO 15 mm ID/22 mm OD conical
Graphical Patient Data
Intelligent Panel
Dynamic Lung2, Vent Status, ASV Graph3, SMPs (Secondary monitoring parameter)
Waveform
Pressure, Flow, Volume, Off, PCO21, FCO21, Plethysmogram1, Ptrachea, Pes, Ptranspulm
Trend
1, 6, 12, 24, or 72-h trend data for a selected parameter or combination of parameters
Loops
Pressure/Volume, Pressure/Flow, Volume/Flow, Volume/PCO21, Volume/FCO21, Pes/Volume, Ptranspulm/Volume
Additional Details
Power Supply
100 to 240 V AC ±10%, 50/60 Hz
Display Size
17 inch (431.8 mm) diagonal
Display Type
Color TFT
Battery Backup
≥90 minutes with one battery / ≥180 minutes with two batteries
Weight
Monitor 7.8 kg (17.2 lb), with shelf mount: 10.0 kg (22.0 lb), Ventilation unit, shelf mount: 10.5 kg (23.15 lb)
Apnea Backup Type
On, Off
Inspiratory Pressure Limit
0 to 100 cm H2O
Alarms
High: Apnea time (s), Exp ManVel high/low (l/min), Oxygen high/low (%), Pressure high/low (cmH2O), Flow sensor calibration needed, Exhalation obstructed, Disconnection, Oxygen supply failed Medium: Total high/low (b/min), PetCO2 high/low (mmHg), Pressure limitation (cmH2O), Vt high/low (ml), SpO2 high/low, SpOC high/low,%leak, High PEEP, Loss of PEEP, Pulse high/low, Check flow sensor for water Low: High SpO2, Loss of external power, Cuff leak
I:E Ratio
Adult/Ped: 1:9 to 4:1, Neonatal: 1:9 to 4:1
Automatic Expiratory Base Flow
Fixed at 6 L/min
Means of Inspiratory Triggering
Flow trigger control, pressure trigger control, or optional IntelliSync + control
Means of Expiratory Triggering
Flow cycle (ETS), or optional IntelliSync + control
Minimum expiratory time
20% of cycle time; 0.2 to 0.8 s
Oxygen Mixer Accuracy
± (Volume fraction of 2.5% + 2.5% of actual reading)
Preoperational Checks
Tightness test, flow sensor/O2 sensor/CO2 sensor calibration
Features
Independent air supply
Real-time synchronization with IntelliSync+
P/V Tool Pro for lung assessment and recruitment
Transpulmonary pressure measurement
Integrated automatic cuff pressure controller
HIgh Flow Oxygen Therapy
Applications
ICU, Critical Care and Transport